Calibration of scintillation detectors using a specific luminescence model
K. Michaelian, A. Menchaca-Rocha and E. Belmont-Moreno1
Instituto de Física, Universidad Nacional Autónoma de México, A.P. 20-364, 01000, México D.F., Mexico
Received 23 February 1993. Available online 25 October 2002.
An algorithm is described which determines the light response function L(E) for scintillation detectors using a specific luminescence model. The light response is simulated from purely physical principles and normalized to the experimental L vs ΔE data. Calibration of the detector is therefore facilitated by requiring fewer (L, ΔE) points, and can be safely interpolated or extrapolated into regions where calibration points do not exist. This article describes the algorithm as applied to data from Si---CsI(Tl) ΔE−L arrays, however, its potential application is more general.
1 On leave at Departamento de Física Aplicada, Universidad de Alicante, Spain.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Volume 334, Issues 2-3 , 1 October 1993, Pages 457-460 |