Fisica Medica
Publicaciones

2021

Out-of-field mean photon energy and dose from 6 MV and 6 MV FFF beams measured with TLD-300 and TLD-100 dosimeters
López-Guadalupe VM, Rodríguez-Laguna A, Poitevin-Chacón MA, López-Pineda E and Brandan ME, Med. Phys. 48 (2021), 6567-6577. https://doi.org/10.1002/mp.15233

Dosimetric Evaluation in Micro-CT Studies Used in Preclinical Molecular Imaging
Rueda AN, Ruiz-Trejo C, López-Pineda E, Romero-Piña ME, Medina LA, Applied Sciences. 2021; 11(17):7930. https://doi.org/10.3390/app11177930

Ultrasound scatterer density classification using convolutional neural networks by exploiting patch statistics
A. K. Z. Tehrani, M. Amiri, I. M. Rosado-Mendez, T. J. Hall, H. Rivaz, IEEE Trans. Ultrason. Ferroelect. Freq. Contrl. 68 (2021), 269. https://arxiv.org/abs/2012.02738

Effect of the Mexico City's air density in low-energy X-ray spectra and its influence in the air kerma and absorbed depth-dose to water
Adriana Moreno-Ramírez andG Massillon-JL, Journal of Instrumentation. (2021) 16 P09014

Electron and photon energy spectra outside of 6 MV X-ray small radiotherapy field edges produced by a Varian iX linac
Nahum Xicohténcatl-Hernández, Adriana Moreno-Ramirez and Guerda Massillon-JL, Frontiers in Physics. (2021) 9 656922

Thermoluminescent relative efficiency of TLD-100 glow peaks after exposure to X-rays of 20 kV-300 kV, 137Cs and 60Co gamma
E. Arzaga-Barajas, G. Massillon-JL, Radiation Measurements 146 (2021) 106635

Stopping power and CSDA range of electrons in liquid water, LiF, CaF2, and Al2O3 from the energy gap up to 433 keV
L.R. Castillo-Rico, M.A. Flores-Mancera and G. Massillon-JL, Nucl. Instr. Meth. Phys. Res. B 502 (2021) 189-197

Future directions on low-energy radiation dosimetry
G. Massillon-JL, Scientific Reports (2021) 11 10569

Shear Wave Dispersion as a Potential Biomarker for Cervical Remodeling During Pregnancy: Evidence from a Non-Human Primate Model
Torres A, Palmeri ML, Feltovich H, Hall TJ, Rosado-Mendez IM. Frontiers in Physics, (2021) 8:606664. https://doi.org/10.3389/fphy.2020.606664

High-resolution Micro-CT myelography to assess spinal subarachnoid space changes after spinal cord injury in rats,
Zambrano-Rodríguez PC, Bolaños-Puchet S, Reyes-Alva HJ, de Los Santos RA, Martínez- Cruz A, Guízar-Sahagún G*, and Medina LA*, Journal of Neuroimaging, (2021) 31 79-89. https://doi.org/10.1111/jon.12813

Femur absorptiometry changes determined by X-ray image segmentation in mice under experimental diabetes and ovariectomy
Flores-Reyes M, Torres-García E*, Oros-Pantoja R, Díaz-Sánchez LE, Mercado-Quintero AV, Medina-Velázquez LA, Applied Radiation and Isotopes 170 (2021) 109608. https://doi.org/10.1016/j.apradiso.2021.109608

In Vivo Study on Bone Response to 3D-Printed Constructs Designed from Microtomographic Images
Pérez-Sánchez L, Ortiz de la O MA, González-Alva P, Medina LA, Masuoka-Ito D, Alvarez-Perez MA* and Serrano-Bello J*, J. of Mater Eng and Perform (2021). https://doi.org/10.1007/s11665-021-05585-8